Best bed probe for your printer: BLTouch, inductive, eddy current or load cell

By Sina Esfahani, OmniTechs · Published 27 November 2026

Every bed probe does the same job: it measures the height of the bed at a grid of points, so the firmware can follow the surface with a mesh. The types differ in what they sense.

A pin probe such as the BLTouch touches the surface, so it works on any bed. Inductive and eddy-current sensors detect the metal under the surface without touching it, so they need a steel or aluminium bed, dislike magnets and drift a little with temperature. Load cells and other nozzle-contact sensors measure with the nozzle itself, which removes the probe offset but needs a clean nozzle.

The best probe is therefore the one that suits your bed and your firmware. If your printer already measures with the nozzle, as Prusa's MK4, Bambu Lab's printers and Creality's K1 Max do, an add-on brings nothing.

Choose and set it up in this order:

  1. Check what is built in; a Prusa MK4, a Bambu Lab printer or a K1 Max needs calibration, not a new probe.

  2. Look at the bed: glass, a non-metal plate or embedded magnets call for a contact probe.

  3. Match the firmware: Marlin takes switch-type probes; eddy-current scanning is documented for Klipper.

  4. Mount it at the maker's height, such as a BLTouch pin about 2 mm above the nozzle when retracted (Klipper).

  5. Switch off and unplug before wiring, and let the hotend and bed cool.

  6. Test it: PROBE_ACCURACY on Klipper or M48 on Marlin; a range above 0.025 mm is not good enough (Klipper).

  7. Probe at one consistent temperature, then set the Z offset.

The probe types side by side

How each probe type measures, and what it needs

From the Antclabs BLTouch page, Prusa's temperature calibration article, Omron's E2K-X datasheet, the Klipper probe, eddy-current and load-cell documentation, Beacon's and Cartographer's setup notes, Bambu Lab's homing guide and Marlin's probe settings, read 27 November 2026.
TypeHow it sensesBed surfaceTemperature behaviourFirmware support
Pin probe (BLTouch, CR Touch, 3DTouch)A retractable pin touches the bed; a Hall sensor sees it liftAny material: glass, wood, metal (Antclabs)No temperature figure published; Antclabs gives a repeatability of about 0.005 mm standard deviationMarlin BLTOUCH, Klipper [bltouch]; some clones lack features (Klipper)
Inductive (Prusa SuperPINDA, LJ12A3 and similar)Detects metal without contact and switches at a set distanceMetal only; the distance depends on the metal and its thickness (Antclabs)All inductive probes change their sensing distance as they warm up (Prusa)Marlin FIX_MOUNTED_PROBE, Klipper [probe]
CapacitiveDetects almost any object without contactDistance varies with material and water content (Omron)Up to ±20% change in sensing distance over the rated range (Omron E2K-X)Same as inductive
Eddy-current scanner (Beacon, Cartographer, BTT Eddy)A coil's resonant frequency rises as it nears metal, which gives a distanceMetal bed or metal under the surface; Cartographer not with embedded magnetsThermal drift: calibrate and probe at the same temperature (Klipper)Klipper [probe_eddy_current] for LDC1612 probes such as the BTT Eddy; Beacon and Cartographer use their own Klipper modules
Load cell or force sensorThe nozzle presses on the bed and the force is measuredAny rigid surface; the nozzle tip must be clean (Bambu Lab)Probe below the ooze temperature; Klipper suggests 140 °CBuilt in on Prusa MK4 and XL and Bambu Lab X1, P1 and A1 mini; Klipper [load_cell_probe]; Marlin NOZZLE_AS_PROBE

A note on the word levelling: no probe makes the bed level. It measures the surface so the firmware can compensate, as an accepted answer on the 3D Printing Stack Exchange explains. What a mesh corrects, and what it cannot, is covered in bed levelling: manual or automatic mesh.

Which probe fits your situation

Choosing a probe

Based on Marlin's and Klipper's probe documentation, Beacon's and Cartographer's notes and an answer on the 3D Printing Stack Exchange about magnets, read 27 November 2026.
Your situationBest fitWhy
Printer with a built-in nozzle sensor or load cellKeep it and run its calibrationIt already measures where the nozzle really is
Marlin printer with glass or a magnetic flex platePin probe (BLTouch type)Works on any surface; Marlin supports it directly
Bare steel sheet or aluminium bed, no magnetsPin probe or inductive sensorInductive has no moving parts, but mind its temperature drift
Klipper printer, you want a fast, dense meshEddy-current scannerIt scans the bed with horizontal moves only (Klipper)
Klipper printer, you swap nozzles oftenNozzle contact: eddy "tap", load cell or Beacon ContactIt measures the actual nozzle, so no offset to redo
Magnets under the platePin probeMagnets can trigger inductive sensors; Cartographer rules them out

How to test whether a probe is good enough

Repeatability matters more than any advertised resolution. Klipper's PROBE_ACCURACY probes the same spot ten times and reports the range between the highest and lowest result. Ideally all ten agree; a difference of one Z step, or up to 5 microns, is normal. If the range is above 25 microns (0.025 mm), Klipper says the probe is not accurate enough for bed levelling. On Marlin, M48 does the same job and reports a standard deviation; M48 P10 runs ten probes.

Worked example: is this result normal?

Your Z axis has an 8 mm lead screw (rotation_distance 8), a 200-step motor and 16 microsteps. One step is 8 ÷ (200 × 16) = 0.0025 mm. PROBE_ACCURACY reports a range of 0.0025 mm: one step, which is perfect. Had it reported 0.030 mm, that would be above Klipper's 0.025 mm limit. Try a slower probing speed or a different start height, as Klipper suggests, then test again. Klipper's last word on a probe that never gets there: do not use it for levelling.

Klipper also suggests a temperature check. Run PROBE_ACCURACY with the printer cold, heat the bed and nozzle to printing temperature and run it again. If the results shift, always probe at the same temperature.

Pin, inductive and capacitive probes

Pin probes (the BLTouch and the many clones such as CR Touch and 3DTouch) are a common upgrade for Marlin printers: they work on any surface, and Marlin supports them directly with its BLTOUCH option. Klipper's documentation warns that some clones lack features, such as touch mode, and that older BLTouch versions and some clones can be less accurate with it. Self-test failures, alarms and offsets are covered in BLTouch and CR Touch problems.

Inductive sensors have no moving parts but see only metal. Prusa states that all inductive probes change their sensing distance as they warm up. Its PINDA v2 carries a thermistor so the firmware can compensate; the SuperPINDA on the MK3S+ has none and needs no temperature calibration. Two practical warnings come from the forums. Magnets in the bed can trigger the sensor as it passes over them. And many cheap sensors are rated for 6 to 36 V: powered at 24 V, their output must not reach a 3.3 or 5 V board input directly. An accepted answer on the 3D Printing Stack Exchange suggests an optocoupler module or a voltage divider in between.

Capacitive sensors detect almost any material, but Omron's datasheet for its E2K-X range says the sensing distance varies with the material and its water content, that water or condensation can be falsely detected, and that the distance can shift by up to 20% over the rated temperature range. So expect the trigger height to move as the printer warms up.

In this test, Aurora Tech measures the BLTouch, a 3DTouch clone, the CR Touch, a strain-gauge sensor and Prusa's SuperPINDA side by side.

The Best Auto Bed Leveling Sensor BL Touch, 3D Touch, CR Touch, Strain Gauge or the Prusa SuperPINDA (Aurora Tech)

Eddy-current scanners: Beacon, Cartographer and BTT Eddy

An eddy-current probe measures the resonant frequency of a coil, which rises the closer the coil is to a metal bed (Klipper). Because it gives a distance rather than a single trigger point, Klipper can scan: the toolhead stays at one height and the probe reads the whole bed during horizontal moves. Klipper's example is BED_MESH_CALIBRATE METHOD=scan HORIZONTAL_MOVE_Z=1, run only after the bed has been checked to be parallel to the rails.

What to watch:

  • Mounting height. BIGTREETECH mounts the Eddy 2 to 3 mm above the bed with the nozzle just touching it; Cartographer asks for 2.6 to 3 mm.

  • Thermal drift. Changes in bed or sensor temperature shift the readings by a few microns, and microns are the scale a probe works at (Klipper). Calibrate and probe at the same temperature. The BTT Eddy USB has a temperature compensation routine; the Eddy Coil has none, which BIGTREETECH says can make it less reliable for homing in a sealed chamber.

  • The bed. Beacon's documentation asks for a metal bed or a metal layer under the surface. Cartographer is not compatible with beds that have embedded magnets.

  • Firmware. Klipper's main release supports LDC1612-based probes such as the BTT Eddy through its [probe_eddy_current] section; BIGTREETECH says the Eddy no longer needs its own Klipper fork. Beacon and Cartographer each install their own Klipper module.

Klipper's "tap" method, and Beacon Contact, let the nozzle touch the bed and use the sensor to see the contact. That measures the real nozzle position with no thermal drift, but the nozzle and bed must be clean, the nozzle must start 3 to 20 mm above the bed, and a hot nozzle can mark a PEI surface (Klipper). YGK3D's comparison of the BTT Eddy and Beacon has chapters on how they work, thermal drift and Beacon Contact.

3D Printer Bed Mesh Generation Will NEVER Be The Same - Eddy v.s. Beacon (YGK3D)

Load cells and nozzle-contact sensors

Many current printers measure with the nozzle itself, so check yours before you buy anything.

  • Prusa MK4/S, MK3.9/S and XL: a load cell in the hotend heatsink senses the nozzle reaching the steel sheet. Prusa says the first layer calibration then runs automatically during mesh levelling, so Live Z adjustment is not needed.

  • Bambu Lab X1 and P1: the printer homes Z by detecting the force of the nozzle on the heatbed, so Bambu Lab asks for a clean nozzle tip and a rigid plate. The A1 has an eddy-current sensor in its hotend that detects the contact, the A1 mini measures the force on the hotend, and the H2D has two eddy-current sensors.

  • Creality K1 Max: strain sensors in the heatbed build the mesh, and its LiDAR scans the first layer (Creality).

  • Klipper: a [load_cell_probe] turns a load cell into a probe. Klipper calls oozing filament the main source of load-cell probing errors and suggests probing at about 140 °C, which also protects PEI. On Marlin, NOZZLE_AS_PROBE with PROBE_TARE covers strain-gauge and piezo nozzle probes.

When an upgrade is worth it, and when to stop

An upgrade is worth it when you still level by hand before every print, or when your bed is not flat and your printer has no probe at all. It is not worth it when the printer already measures with the nozzle, or when a probe you have cannot pass the repeatability test; Klipper's advice then is to use its manual levelling tools instead.

Stop and check before you power up after fitting a probe. Do all wiring with the printer switched off and unplugged; BIGTREETECH's board manual says never to work on a board with power applied and to double-check jumpers and wiring first. Mellow warns that wiring a BLTouch in the wrong order can permanently damage the sensor and the board. If a new probe crashes the nozzle into the bed, switch off and recheck the wiring and configuration before you try again.

Once the probe works, set the nozzle height with Z offset. If you are planning several changes at once, 3D printer upgrades worth doing maps each problem to the upgrade that solves it. Klipper toolhead boards that carry an eddy probe or accelerometer are covered in Klipper CAN bus toolhead boards.