3D printer fans: which fan does what, which must always run, and how much cooling each filament needs

By Sina Esfahani, OmniTechs · Published 27 November 2026

An FDM printer has two kinds of fan. Protective fans keep parts within their limits and are not yours to switch off: the hotend fan on the heatsink, the board fan and, on many printers, a fan in the power supply. Print fans shape the plastic and change with the material: the part-cooling fan at the nozzle, plus the auxiliary, chamber and exhaust fans of enclosed printers.

The hotend fan matters most. It keeps the heatsink cold so the filament stays solid until it reaches the melt zone. Firmware runs it whenever the nozzle is above 50 °C. If it stops, expect a jam within the first few layers (Prusa).

Check and set your fans in this order:

  1. Identify each fan: heatsink, nozzle duct, board, power supply, chamber or exhaust.

  2. Heat the nozzle above 50 °C and check that the hotend fan spins and blows into the heatsink.

  3. Test the part fan from the printer's menu, or with M106 S255, then M106 S64 and M107.

  4. Use your filament maker's range: high for PLA, moderate for PETG, low for ABS and ASA.

  5. Keep the part fan off for the first layer, and for the first few with ABS and ASA.

  6. Before cleaning or replacing a fan, switch off, unplug and let the hotend cool.

  7. Replace a fan only with one of the same voltage, size and connector, mounted to blow the same way.

The fans on your printer and what each protects

The fans on an FDM printer

From Bambu Lab's fan overview, Prusa's fan articles and Marlin's and Klipper's fan documentation, read on 27 November 2026.
FanWhat it doesWhen it runsYours to change?
Hotend (heatsink) fanKeeps the heatsink and heat break cold so filament does not soften too earlyFrom 50 °C at the nozzle until it cools below 50 °CNo: never while the hotend is hot
Part-cooling fanSolidifies each fresh line: overhangs, bridges, detailSet by the slicer per material and layer; off for the first layerYes, per material
Auxiliary part fan (Bambu Lab P, X and H series)A wide side airflow across the part for fast printingSet by the filament profileYes, per material
Board (controller) fanCools the mainboard and stepper driversWhile motors are enabled or the bed heats, then a set idle timeNo
Power-supply fanCools the supply, where it has onePart of the supply, not a slicer settingNo
Chamber or exhaust fanRemoves hot air and fumes from an enclosureBy chamber temperature or the filament profileThrough the slicer and printer settings

The hotend fan must always run

Heat travels up from the heater block. The hotend fan pulls it out of the heatsink fins, so the filament stays stiff until the melt zone. When the fan slows or stops, the filament softens higher up, sticks to the walls of the heat break and jams: Bambu Lab describes exactly that failure, and Prusa expects the nozzle to jam after the first few layers. Why that happens, and how to clear it, is covered in heat creep.

Where this fan is switched, the firmware does it by temperature and never through the slicer; other printers wire it to an always-on output, which Marlin also allows. Marlin turns it on at EXTRUDER_AUTO_FAN_TEMPERATURE, 50 °C, from the measured temperature, so it keeps running after a print until the nozzle has cooled. Klipper's heater_fan uses the same 50 °C default. Bambu Lab's hotend fan turns on above 50 °C and off below it. On Prusa's MK3-series printers it starts at 50 °C and spins for the whole print.

Two rules follow. Never connect the hotend fan to the part-cooling output: Marlin warns that the slicer switches that output off for the first layers and for ABS, so the heatsink gets no air and the extruder jams. And check the airflow direction: Prusa's rule is that the fan pushes air into and through the heatsink, not out. Cutting the power straight after a print also stops this fan, which is why the hotend should cool first.

How much part cooling each material needs

Cooling helps detail and overhangs but weakens layer bonding and makes some materials warp or crack. Filament makers therefore publish a range per material, and the slicer moves within it. Makers do not all agree, so read the table by material, not as one rule.

Part-cooling fan per material, as the makers publish it

From Bambu Lab's filament guide, Prusa's print-fan, PETG and flexible-filament articles and Polymaker's wiki page for its PETG, read on 27 November 2026. Polymaker ties the ends of its range to layer time; Bambu Lab's guide gives the range only.
MaterialBambu Lab filament guidePrusaPolymaker
PLAPLA Basic 50 to 100%100% for the whole print, from layer 2 to 4Not used here
PETGPETG Basic 0 to 60%Off for the first few layers, then half power; off for maximum toughnessPolymaker PETG 20 to 60%
ABS and ASA0 to 80%Off for the first 4 layers, then 15 to 20%, a little more on bridgesNot used here
TPUTPU 95A HF 50 to 100%Keep print cooling off (flexible filaments)Not used here

Note the TPU row: Bambu Lab cools its TPU 95A HF hard, while Prusa's advice for flexible filaments is to keep cooling off. Start from the profile your filament's maker publishes. Fan speed for overhangs and bridges has its own tuning, covered in overhangs and bridges.

Worked example: how the slicer picks a speed

Polymaker's PETG page gives two points: a minimum of 20% at a layer time of 30 seconds and a maximum of 60% at 10 seconds. PrusaSlicer runs the fan at its minimum for slow layers, at its maximum for fast layers and proportionally in between. A small part whose layers take 20 seconds sits halfway, so the fan runs at about 40%. A large plate with 60-second layers stays at 20%, provided Keep fan always on is set; without it, PrusaSlicer switches the fan off for layers longer than the threshold. That is why the same filament gets more cooling on small parts.

Why the first layer prints without the fan

The first layer is laid on a flat bed, so it needs no cooling to hold its shape, and cooling it works against adhesion (PrusaSlicer). An accepted answer on the 3D Printing Stack Exchange gives the mechanism: plastic shrinks as it cools, so a fan on the first layer pulls it away from the bed. With many filaments PrusaSlicer suggests skipping cooling for a few more layers, typically 1 to 5, to prevent warping. Prusa's own profiles start the fan between layers 2 and 4.

Where to set it:

  • Bambu Studio 2.9: filament settings, Cooling, Initial layer fan: For the first, a number of layers, and Fan speed. Bambu Studio's default is one layer.

  • OrcaSlicer: filament settings, Cooling, Cooling for specific layer, No cooling for the first.

  • PrusaSlicer: Filament Settings, Cooling, Disable fan for the first.

  • UltiMaker Cura 5.14: Cooling, Initial Fan Speed (0% by default) and Regular Fan Speed at Layer (layer 2 by default).

Auxiliary, chamber and exhaust fans

Bambu Lab's auxiliary part cooling fan is a 12 W fan on the left of the chamber that blows across the part for high-speed printing. Bambu Studio's PLA and TPU profiles run it at 70% and its PETG, ABS and ASA profiles leave it off; you set it under Cooling, Auxiliary part cooling fan.

The chamber temperature regulator fan on the X1 and P1S removes hot air when the chamber gets too warm. For PLA, Bambu Lab turns it on once the bed is set above 50 °C, and its heat-creep page asks you to keep an enclosure at least 10 °C below the filament's glass transition temperature. For PLA on an enclosed printer, Bambu Lab suggests opening the front door or removing the top cover, unless you print on its Cool Plate at a 35 °C bed.

Enclosing an open printer changes the board fan too. Bambu Lab's P1P was designed to run without a board fan when open. Once enclosed, it needs the MC board fan, turned on with M710 A1 S255, before you print high-temperature filament. Fumes from ABS and ASA are a separate subject: see printing ABS and ASA.

Test a fan and read its error

Test with the printer cold first, then hot.

  1. Part fan. Send M106 S255; it should reach full speed within a moment. M106 S64 and M106 S20 should still turn it; M107 stops it (Marlin). On a Prusa MK3, use Settings, Temperature, Fan speed at 127 to 255.

  2. Hotend fan. Set the nozzle to 60 °C (M104 S60): the fan starts within seconds of passing 50 °C. Set it to 0 and it keeps running until the nozzle is below 50 °C. Bambu Lab's check sets 51 °C.

  3. Board fan. Send M17 or home the printer; the fan starts within 2.5 seconds. After M84 it runs on for the idle time, 60 seconds in Marlin and 30 seconds by default in Klipper, and then switches off by default.

On Klipper, M106 drives the [fan] section; an extra fan defined as fan_generic takes SET_FAN_SPEED FAN=name SPEED=1. Klipper's controller_fan starts only once a stepper or heater is active, never at power-up. For a board fan that must run from the start, wire it to an always-on output, or define it as fan_generic and switch it on with a delayed_gcode that has initial_duration: 1, as an administrator of the Klipper forum suggests.

Fan errors and what they mean

From Prusa's fan error articles, Bambu Lab's HMS pages 0300-0300-0001-0001 and 0300-0400-0002-0001, and Marlin's and Klipper's fan documentation, read on 27 November 2026.
What you seeWhat it meansWhat to do
Prusa: PRINT FAN ERRORNo speed reading: the fan does not spin, or its yellow signal wire is brokenClear debris; check the RPM in Support, Extruder info while moving the head; replace the fan if it drops to zero
Bambu Lab: the hotend cooling fan speed is too slow or stoppedA blade blocked by filament strings, a loose connector, a broken fan or boardPower off; free the blades; reseat the 4-pin cable; replace the fan
Bambu Lab: the part cooling fan speed is too slow or stoppedDebris, a loose connector or a worn fan motorTurn the fan off, check by hand, reseat, replace if needed
Marlin: Error:Fan speed E0A monitored hotend fan below 1,200 RPM for about 5 secondsCheck the fan turns freely and its tachometer wiring
The part fan will not start at low slicer speedsIt cannot start at that powerMarlin: FAN_MIN_PWM and FAN_KICKSTART_TIME; Klipper: off_below and kick_start_time
THERMAL RUNAWAY when the part fan startsThe duct blows on the heater blockFit a silicone sock and aim the duct at the nozzle tip

If the heater error persists after fixing the duct, work through the thermal runaway guide.

Replace a fan safely, and when to stop

Switch the printer off, unplug it and let the hotend cool before you touch a fan. Bambu Lab insists on this for all maintenance, because a loose toolhead wire touching metal on a powered printer can short and damage the electronics. Prusa adds that you should also unplug the USB cable.

  • Match the part. Same voltage (12 V or 24 V), size, connector and airflow direction. Marlin notes that a 12 V fan on a 24 V printer still sees 24 V pulses, even with a lower duty set; a fan rated for the printer's voltage is the safer choice.

  • Clean before you replace. Prusa's tip: hold the blades still while you blow dust out with canned air, or you can damage the motor. Creality's list for a fan that does not turn or rattles: clean it, tighten its screws and cover, and replace it if a blade is damaged.

  • Speed sensing. If your replacement has no speed wire, a Prusa MK3 reports an error until you turn off Settings, Check fans.

Bryan Vines replaces the hotend and part fans on an Ender 3 and fits connectors that make the next swap a plug-in job.

How To Replace the Fans on your 3D Printer for Easy Future Maintenance (BV3D: Bryan Vines)

Stop printing until the fan is replaced if the hotend fan is damaged, slow or missing blades: Bambu Lab ties a slow hotend fan directly to jams in the heat break. Stop too if a duct has melted or you smell burning; then also look for the cause, such as a duct too close to the heater block.

Firmware settings for each fan

Fan settings in Marlin and Klipper

Defaults from Marlin's fan documentation and Klipper's configuration reference, read on 27 November 2026.
FanMarlinKlipper
Part-coolingM106 S0 to S255, M107 off; FAN0_PIN[fan]; M106 and M107
HotendE0_AUTO_FAN_PIN, EXTRUDER_AUTO_FAN_TEMPERATURE 50 °C[heater_fan], heater_temp: 50.0
BoardUSE_CONTROLLER_FAN, CONTROLLERFAN_IDLE_TIME 60 s, M710 at run time[controller_fan], idle_timeout 30 s by default
Extra fansM106 P1 and up[fan_generic] with SET_FAN_SPEED
ChamberCHAMBER_AUTO_FAN_PIN at 30 °C[temperature_fan], target_temp 40 °C by default
Low-speed startFAN_MIN_PWM, FAN_KICKSTART_TIMEoff_below, kick_start_time 0.1 s

Slicers show fan speed as a percentage but send 0 to 255 in M106; the conversion is in the G-code commands guide. Fan noise and whine are covered in printer vibration and noise.