3D printer calibration order: what to calibrate first, and what your printer already does
By Sina Esfahani, OmniTechs · Published 27 November 2026
Calibrate so that each test builds only on what is already right. Start with the mechanics and the printer itself: belts, bed, heaters, first layer and vibration. Then calibrate each filament: temperature, maximum flow, pressure advance, flow ratio and retraction. Check dimensions last. A wrong temperature or a loose belt spoils every test after it; OrcaSlicer's guide asks you to follow its order for exactly that reason.
Most current printers do the printer half themselves. Bambu Lab printers run a calibration from the screen that covers vibration compensation and bed levelling; Prusa's MK4S and CORE One run a self-test and ship with input shaping calibrated at the factory; Creality's K1 series runs input shaping and bed levelling in its self-check. On those, run the built-in routine, skip what it covers, and calibrate per filament.
Calibrate in this order:
Mechanics, with the printer switched off and unplugged: belt tension, loose screws and wheels, a clean plate, a trammed bed.
The printer's own routines: Bambu Lab's calibration, Prusa's first-run wizard, Creality's Self-check; on a Marlin or Klipper printer, PID tuning and a bed mesh.
The first layer: Z offset and a first-layer test print.
Per filament: a temperature tower within the maker's range.
Per filament: maximum volumetric speed, used 10 to 20% below the test result (OrcaSlicer).
Per filament: pressure advance (Bambu Lab calls it flow dynamics), then flow ratio, then retraction only if it strings.
Dimensions and tolerances last, and only if parts must fit together.
What your printer already does, and what is left
Built-in calibration per printer family and what remains for you
| Printer | What it calibrates itself | What is left for you |
|---|---|---|
| Bambu Lab A1, P1, X1 | A screen calibration: vibration compensation with a frequency sweep and bed levelling, plus motor noise cancellation on the A1 | Flow dynamics for a new brand or nozzle (automatic on A1 and X1, manual on P1); flow rate only if defects remain |
| Bambu Lab H2D | Motor noise cancellation, vibration compensation, auto and high-temperature bed levelling, nozzle offset and motion accuracy calibration | As above, with automatic flow dynamics |
| Prusa MK4S and CORE One | First-run wizard: self-test, loadcell test, gearbox alignment, filament sensor; input shaper calibrated at the factory | Prusa's filament profiles; extrusion multiplier only as an advanced step |
| Creality K1 and K1 Max | Self-check with input shaping and auto bed levelling; the K1 Max can also calibrate pressure advance with its AI lidar | Temperature, flow and retraction for other brands |
| A Marlin or Klipper printer you set up yourself | A bed mesh, if it has a probe | Everything: PID, e-steps, Z offset, input shaping, then each filament |
Step 1: the mechanics come first
Software cannot correct a loose belt, a wobbly wheel or a bed that is far out of tram. Prusa asks you to check that belts are not loose, the nozzle is in good shape and the rods are clean before you rely on input shaping. On Bambu Lab's forum, the most-read calibration guide, with over 200,000 views, starts the same way: a printer new from the box is not necessarily aligned after shipping, so tram the bed before anything else.
Switch the printer off and unplug it for these checks. Then work through belt tension, manual and automatic bed levelling and, if axes feel rough, lubricating rails and lead screws.
Step 2: run the printer's own calibration
Bambu Lab. The X1 runs its calibration during first setup; start it again under Utilities, Calibrate (X1) or Settings, Calibration (P1). On the A1 it covers motor noise cancellation, vibration compensation and auto bed levelling; the H2D adds high-temperature bed levelling, nozzle offset and motion accuracy calibration. After you change the heatbed, build plate, hotend or heating assembly, Bambu Lab strongly recommends bed levelling from the calibration page (A1). Before each print you can also tick bed levelling and flow dynamics calibration.
Prusa MK4S and CORE One. The wizard starts after the first power-up or a factory reset and runs the self-test, the loadcell test, gearbox alignment and the filament sensor calibration. Keep the door closed until it asks you to open it: Prusa warns there are hot and moving parts inside. The input shaper is calibrated at the factory; recalibrate it with the optional accelerometer only after hardware modifications (Prusa).
Creality K1 series. After a firmware update, Creality asks you to open Settings, Self-check, tick Input Shaping and Auto Bed Leveling, and start it before printing. On the K1 Max, the AI lidar can calibrate flow before each print; it is off from the factory and is switched on under the camera and AI settings.
Marlin and Klipper printers you built or converted. Nothing is automatic, so do these in order: Klipper's configuration checks, PID tuning of hotend and bed (PID_CALIBRATE on Klipper; on Marlin M303 with U1, so the result is used, then M500; see the thermal runaway guide), e-steps or rotation distance, the Z offset, then input shaping.
Step 3: calibrate each new filament in this order
OrcaSlicer's calibration guide sets the order and the reason for each step. Repeat it for every new filament, in the Calibration menu of OrcaSlicer 2.5.2 (Temperature, Max flowrate, Pressure advance, Flow ratio, Retraction):
Temperature. It sets how the plastic flows and sticks, so every later test depends on it. Start from the maker's range with a temperature tower.
Maximum volumetric speed. It caps how fast the hotend can melt this filament. OrcaSlicer warns that makers sometimes overstate it and advises a value 10 to 20% below your result.
Pressure advance. OrcaSlicer puts it before flow because it is the value most often wrong, and cleaner corners make the flow test easier to read; see pressure advance and linear advance.
Flow ratio. Usually a small correction to the profile's value; see flow rate calibration. If it changed a lot, run a quick pressure advance test again.
Retraction. The defaults usually work; tune it last, because pressure advance and flow change the pressure in the nozzle. See retraction settings.
In Bambu Studio, flow dynamics and flow rate calibration sit on the Calibration tab. For a Bambu Lab printer, Bambu Studio shows its temperature, max flowrate and retraction tests only with Develop mode switched on in Preferences; OrcaSlicer shows them for every printer. Bambu Lab asks for a flow dynamics calibration when you use a filament of a new brand or model, when the nozzle is worn or replaced, and when you change the maximum volumetric speed or print temperature. With Bambu Lab printers and Bambu Lab filament, it keeps flow rate calibration for defects that remain after the other calibrations.
Factorian Designs walks through this five-step filament calibration in OrcaSlicer; the OrcaSlicer wiki links to the same video.
Worked example: a new PETG on a Bambu Lab A1
The printer's calibration ran at setup, so you start with the filament. The spool says 230 to 250 °C. A temperature tower across that range looks best at 240 °C. The maximum volumetric speed test prints cleanly up to 14 mm³/s; 10 to 20% below that is 11.2 to 12.6, so you enter 12 mm³/s. Because it is a new brand, you run automatic flow dynamics calibration, which the A1 supports from firmware 01.04.00.00. Top surfaces look even and nothing strings, so you skip flow ratio and retraction. Three tests, done.
When you can skip a step
Which calibrations to skip, and when to do them anyway
| Step | Skip it when | Do it when |
|---|---|---|
| E-steps or rotation distance | The printer is Bambu Lab or Prusa, or new and factory-set | You change the extruder or its gears on a Marlin or Klipper printer |
| PID tuning | The printer handles its own heaters | After installing Klipper, or a new heater, thermistor or heater block |
| Input shaping | The printer measures it itself, or it was calibrated at the factory | After belt, frame or toolhead changes |
| Pressure advance | The printer calibrates flow dynamics automatically for that filament | A new brand, a new nozzle, or bulging corners |
| Flow ratio | Surfaces look right | Over- or under-extrusion remains after the earlier steps |
| Retraction | The default does not string | Stringing remains after temperature and pressure advance |
| Tolerance and dimensions | Parts do not need to fit | Holes, slots or mating parts come out wrong |
OrcaSlicer also lists optional advanced tests, such as cornering, VFA and adaptive pressure advance, that mostly tune the printer rather than the filament; it says most printers do not need the cornering test.
Which test prints actually help
A test that isolates one variable tells you more than a model that shows everything at once. The calibration models in OrcaSlicer and Bambu Studio change one setting per band, line or block, so you can read off the value. A Benchy is not a calibration test: the accepted answer on the 3D Printing Stack Exchange calls it a general benchmark that shows many common problems, after which you go back to a single-variable test. A calibration cube measures dimensions, but only after flow is right; calibrating dimensional accuracy explains what to measure, and tolerances and clearance covers designing parts that fit.
When the numbers will not settle
Stop tuning when results jump between runs. Bambu Lab names the usual causes of unreliable flow dynamics results: damp filament, transparent filament on X1 printers (the lidar cannot read it well), a plate the lines do not stick to, a worn or partly blocked nozzle, soft filament such as TPU, and third-party hotends. It also says repeated automatic runs vary by about 10%. Check for wet filament and a clogged nozzle before you test again.
Next step and related guides
Each step above has its own guide. If you are adding filament from another brand to a Bambu Lab AMS, third-party filament profiles shows how to create the profile that these calibrations are saved to.